  eco-1 rev.: 2/2017 www.recom-power.com 6 watt sip8 single and dual output dc/dc converter features regulated converters ? highest power density in sip package ? 1.6kvdc/1 minute isolation ? effciency up to 88% ? -40c to +75c operating temperature range @ full load ? en60950 and ul/en62368-1 (pending) cb report ? industry standard pinout rs6 en60950-1 (pending) en62368-1 (pending) ul62368-1 (pending) en55022 compliant description the rs6 series offer very high power density (2.7w/cm3), wide input voltage range and an industrial operating temperature range of -40c to +75c without derating. high effciency, tight regulation, 2kvdc isolation and remote on/off are just some of the characteristics of this advanced sip8 6w converter which is ideal for high density power supply designs in demanding industrial applications. 3 y e a r w a r r a n t y 3 selection guide part nom. input output output effciency max. capacitive number voltage voltage current typ. (1) load (2) [vdc] [vdc] [ma] [%] [f] rs6-053.3s 5 3.3 1300 83 6600 rs6-0505s 5 5 1200 86 3300 rs6-0512s 5 12 500 87 1600 rs6-0515s 5 15 400 86 1400 RS6-0505D 5 5 600 84 2000 rs6-0512d 5 12 250 87 900 rs6-0515d 5 15 200 86 660 rs6-123.3s 12 3.3 1300 81 6600 rs6-1205s 12 5 1200 86 3300 rs6-1212s 12 12 500 87 1600 rs6-1215s 12 15 400 87 1400 rs6-1205d 12 5 600 85 2000 rs6-1212d 12 12 250 87 900 rs6-1215d 12 15 200 87 660 rs6-243.3s 24 3.3 1300 81 6600 rs6-2405s 24 5 1200 87 3300 rs6-2412s 24 12 500 87 1600 rs6-2415s 24 15 400 87 1400 rs6-2405d 24 5 600 85 2000 rs6-2412d 24 12 250 87 900 rs6-2415d 24 15 200 87 660 rs6-483.3s 48 3.3 1300 81 6600 rs6-4805s 48 5 1200 87 3300 rs6-4812s 48 12 500 87 1600 rs6-4815s 48 15 400 88 1400 rs6-4805d 48 5 600 85 2000 rs6-4812d 48 12 250 87 900 rs6-4815d 48 15 200 88 660 notes: note1: effciency tested at nominal input and full load at +25c ambient. note2: max cap load tested at minimum input and constant resistor load.
basic characteristics parameter condition min. typ. max. input filter capacitor input voltage range nom. vin= 5vdc 12vdc 24vdc 48vdc 4.5vdc 9vdc 18vdc 36vdc 5vdc 12vdc 24vdc 48vdc 9vdc 18vdc 36vdc 75vdc input surge voltage 1 second max. nom. vin= 5vdc 12vdc 24vdc 48vdc 15vdc 25vdc 50vdc 100vdc quiescent current nom. vin= 5vdc 2vdc 24vdc 48vdc 105ma 55ma 28ma 14ma output voltage trimming see calculation on next page trim up trim down +10% -8% start-up time 2ms under voltage lockout nom. vin= 5v dc-dc on dc-dc off 4.5vdc 2.7vdc nom. vin= 12v dc-dc on dc-dc off 9vdc 7vdc nom. vin= 24v dc-dc on dc-dc off 18vdc 15vdc nom. vin= 48v dc-dc on dc-dc off 36vdc 30vdc on/off ctrl dc-dc on dc-dc off open 5v continued on next page specifcations (measured @ ta= 25c, nominal input voltage, full load and after warm up unless otherwise specifed) rs6 series eco-3 rev.: 2/2017 www.recom-power.com output voltage trimming trim calculation practical example: trim up trim down vref +vout trim r1 r down r3 r2 vref -vout trim r1 r up r3 r2 vref +vout trim r1 r down r3 r2 vref -vout trim r1 r up r3 r2 vout 3.3v 5v 12v 15v r1 16.74k 10k 38k 50k r2 10k r3 52.3k 39k 68k 68k vref 1.24v 2.5v a = q vref r * r1 = k (vout + d vout) - vref r up = q a*r2 r - r3 = k r2 - a r down = q b*r1 r - r3 = k r1 - b a = q 2.5v r * 10k = 8.33k (5v + 0.5v) - 2.5v b = q (vout + d vout) - vref r * r2 = k vref r up = q 8.33k * 10k r - 39 = 11.0k 10 k - 8.33 k rs6-xx03.3s rs6-xx05s rs6-xx12s rs6-xx15s trim up 1 2 3 4 5 6 7 8 9 10 % vout = 3.33 3.36 3.39 3.43 3.46 3.49 3.53 3.56 3.59 3.63 volts r up = 1151.73 360.87 197.07 126.28 86.79 61.60 44.14 31.32 21.15 13.76 kohms trim up 1 2 3 4 5 6 7 8 9 10 % vout = 5.05 5.10 5.15 5.20 5.25 5.30 5.35 5.4 5.45 5.50 volts r up = 461.00 211.00 127.67 86.00 61.00 44.33 32.43 23.50 16.56 11.00 kohms trim up 1 2 3 4 5 6 7 8 9 10 % vout = 12.12 12.24 12.36 12.48 12.60 12.72 12.84 12.96 13.08 13.20 volts r up = 723.67 327.83 195.89 129.92 90.33 63.94 45.10 30.96 19.96 11.17 kohms trim up 1 2 3 4 5 6 7 8 9 10 % vout = 15.15 15.3 15.45 15.60 15.75 15.90 16.05 16.20 16.35 16.50 volts r up = 765.33 348.67 209.78 140.33 98.67 70.89 51.05 36.17 24.59 15.33 kohms t rim up: vout = 5v, d vout = 0.5v (10%), vref= 2.5v vout = nom. output voltage d vout = output voltage trim r up = trim up resistor r down = trim down resistor a = trim up factor b = trim down factor d vout = vout - vout trimmed dc/dc converter
regulations parameter condition values output accuracy 1.0% typ. line regulation low line to high line 0.2% typ. load regulation 0% to 100% load 1.0% typ. cross regulation 25% to 100% load 5.0% typ. transient response 25% load step change 500s typ. rs6 series specifcations (measured @ ta= 25c, nominal input voltage, full load and after warm up unless otherwise specifed) dc/dc converter eco-4 rev.: 2/2017 www.recom-power.com accuracy vs load rs6-1205s rs6-2405s 9vin 12vin 15vin 18vin 18vin 24vin 30vin 36vin accuracy [%] output load [a] 0 0.1 0.2 0.15 0.25 0.3 0.4 0.35 0.5 0.45 0.5 1.0 1.2 accuracy [%] output load [a] 0 -0.2 -0.25 -0.1 -0.15 -0.05 0 0.1 0.05 0.2 0.15 0.5 1.0 1.2 rs6-xx03.3s rs6-xx05s rs6-xx12s rs6-xx15s trim down -1 -2 -3 -4 -5 -6 -7 -8 % vout = 3.267 3.234 3.201 3.168 3.135 3.102 3.069 3.036 volts r down = 643.60 355.96 233.75 166.13 123.19 93.52 71.78 55.17 kohms trim down -1 -2 -3 -4 -5 -6 -7 -8 % vout = 4.95 4.90 4.85 4.80 4.75 4.70 4.65 4.60 volts r down = 451.00 201.00 117.67 76.00 51.00 34.33 22.43 13.50 kohms trim down -1 -2 -3 -4 -5 -6 -7 -8 % vout = 11.88 11.76 11.64 11.52 11.40 11.28 11.16 11.04 volts r down = 2902.33 1398.17 896.78 646.08 495.67 395.39 323.76 270.04 kohms trim down -1 -2 -3 -4 -5 -6 -7 -8 % vout = 14.85 14.70 14.55 14.40 14.25 14.10 13.95 13.80 volts r down = 4048.67 1965.33 1270.89 923.67 715.33 576.44 477.24 402.83 kohms trim down: vout = 5v, d vout = -0.4v (-8%) , vref= 2.5v b = q [5v + (-0.4v)] - 2.5v r * 10k = 8.4k 2.5v r down = q 8.4k * 10k r - 39k = 13.5 k 10k - 8.4k
environmental parameter condition value operating temperature range (5) without derating (see graph) -40c to +75c maximum case temperature +105c temperature coeffcient 0.02%/c operating humidity non-condensing 5% - 95% rh max. vibration mil-std-202g mtbf according to mil-hdbk-217f, g.b. +25c 1776 x 10 3 hours safety and certifications certifcate type report / file number standard information technology equipment, general requirements for safety (lvd) pending en60950-1, 2nd endition am2 , 2013 audio/video, information and communication technology equipment - safety requirements (cb scheme) pending en62368-1, 2014 ul62368-1, 2nd edition, 2014 can/csa c22.2 no. 62368-1-14, 2014 rohs2 rohs-2011/65/eu + am-2015/863 emc compliance condition standard / criterion information technology equipment - radio disturbance characteristics - limits and methods of measurement with external flter (see flter suggestions) en55022, class a en55022, class b continued on next page dc/dc converter specifcations (measured @ ta= 25c, nominal input voltage, full load and after warm up unless otherwise specifed) rs6 series eco-5 rev.: 2/2017 www.recom-power.com 100 80 70 60 40 20 0 -40 0 60 40 20 -20 100 85 75 120 80 output power [%] ambient temperature [c] safe operating area notes: note5: derating graph is referring to rs6-0505s. for more details, please contact our technical support service at techsupportat@recom-power.com. protections parameter condition value short circuit protection (scp) below 100m continuous, automatic revovery over load protection (olp) 150% load, continuous, autmatic recovery isolation voltage i/p to o/p tested for 1 second rated for 1 minute 2kvdc 1.6kvdc isolation capacitance 110pf max. isolation resistance 1g typ. isolation grade functional derating graph (@ chamber and natural convection 0.1m/s)
esd electrostatic discharge immunity test 8kv air discharge, 6kv contact discharge en61000-4-2, criteria a radiated, radio-frequency, electromagnetic feld immunity test 10v/m en61000-4-3, criteria a fast transient and burst immunity 2kv en61000-4-4, criteria a surge immunity 1kv en61000-4-5, criteria a immunity to conducted disturbances, induced by radio-frequency felds 10vr.m.s en61000-4-6, criteria a rs6 series specifcations (measured @ ta= 25c, nominal input voltage, full load and after warm up unless otherwise specifed) dc/dc converter eco-6 rev.: 2/2017 www.recom-power.com c1 c2 +vin -vin load l1 l1 l2 c1 c2 c4 c5 c3 c6 c7 c8 +vin -vin load emc filtering - suggestions for en55022 class a emc filtering - suggestions for en55022 class b model c1 c2 l1 rs6-05xx 22f n/a 1h cmc rs6-12xx 4.7f 2.2h cmc rs6-24xx 6.8h cmc rs6-48xx 2.2f 2.2f 10h cmc model c1 c2 l1 c3 c4 l2 c5 c6 c7 c8 rs6-05xx 22f n/a 1h cmc 10f n/a 200h cmc 10f n/a 47pf 100pf rs6-12xx 10f 6.8h cmc 4.7f rs6-24xx 4.7f 10h cmc 4.7f 4.7f n/a 33pf 220pf rs6-48xx 2.2f 2.2f 22h cmc 2.2f 2.2f 600h cmc 1f 47pf 680pf surge protection circuit according to en61000-4-5, criteria a c surge d surge +vin -vin load input voltage csurge dsurge max. surge voltage 5vdc 100v, 220f e/cap tvs (p4smaj15ca) 1kvdc 12vdc n/a 24vdc 48vdc
dimension and physical characteristics parameter type value material case potting non conductive plastic (ul94v-0) epoxy (ul94v-0) package dimension (lxwxh) 21.8 x 9.2 x 11.1mm package weight 4.0g the product information and specifcations are subject to change without prior notice. recom products are not authorized for use in safety-critical applications (such as life support) without recoms explicit written consent. a safety-critical application is defned as an application where a failure of a recom product may reasonably be expected to endanger or cause loss of life, infict bodily harm or damage property. the buyer shall indemnify and hold harmless recom, its affliated companies and its representatives against any damage claims in connection with the unauthorized use of recom products in such safety-critical applications. packaging information packaging dimension (lxwxh) tube 520.0 x 18.2 x 11.2mm packaging quantity 22pcs storage temperature range -55c to +125c storage humidity non-condensing 95% rh max. dimension drawing (mm) 0.50 3.2 11.1 0.5 9.2 1.00 ? +0.15/-0 21.8 7 x 2.54 = 17.78 2.0 4.1 0.25 rs6 series 2.54 2.54 1 2 3 6 7 8 5 marking embossed logo bottom view top view recommended footprint details pin connections pin # single dual 1 -vin -vin 2 +vin +vin 3 ctrl ctrl 5 trim nc 6 +vout +vout 7 -vout com 8 nc -vout nc= no connection tolerance: xx.x= 0.5mm xx.xx= 0.25mm pin dimension: 0.1mm pin pitch: 0.25mm dc/dc converter specifcations (measured @ ta= 25c, nominal input voltage, full load and after warm up unless otherwise specifed) rs6 series eco-7 rev.: 2/2017 www.recom-power.com


▲Up To Search▲   

 
Price & Availability of RS6-0505D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X